<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-11 01-16-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.10 MHz 5/5, 66 dBuV MOUV'
Pilot RDS Phase Difference
6.6 kHz 3.7 kHz -82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 71 kHz 10020 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,3 dBr 7,18 dBr 7,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" MOUV' " F208 0 (No PTY) 1 0 1 1 1:16, 11.04.2025
RT
"L'INTEGRALE "
AF EON
91.0, 92.1, 95.8, 101.1 MHz F222, F20A, F204, F202
FM Scope Station: 92.10 MHz, signal: 5/5 (66 dBuV) Max at: 71 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/04/11 1:15:13 Total samples: 10020 Equivalent time: 0:08:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 7,9 dBr MIN: 6,3 dBr AVE: 7,18 dBr % above 10,2 dBr: 0,0 Last value: 6,3 dBr (2025/04/11 1:15:12) Station: 92.10 MHz, signal: 5/5 (66 dBuV) 01:08 01:09 01:10 01:11 01:12 01:13 01:14 01:15 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality